News

22-5-08 Join our winning team , EHS-TECH is looking to expand our worldwide business , if you want to be our partner AND JOIN TO WINING TEAM please send us email OFFICE@EHS-TECH.COM
13-3-08 EHS-Tech Ltd. installed controllers of ACI Ltd. for saving energy in fluorescent light. The conrollers were reduced the light consumption by 18% with keeping the same light intensity.
13-3-08 EHS-Tech Ltd. will provide systems for saving energy and economical lighting for companies in Romania to promote national projects.
9-3-08 Energy saving devices were installed in Home-Centre

Last week energy saving devices were installed in cooling systems (chillers) of Home Centre chain by EHS-Tech.The devices that were installed save 10% from energy consumption. 

9-3-08 EHS- Tech Ltd. start to sell PV cells in Israel for private use and with accordance to the standard of the National Infrastructure Ministry.

The cells are produced in EHS coreporation and they have the highest utilization of more than 16%.

9-3-08 Installation of two lighting pillars with renewable energy

EHS Tech Ltd. will install sorrunds lighting which is based on renewable energies in the first "green supermarket in Israel. The company will provide pillars lighting with LED lighting that will be provided by wind turbines and PV cells.

6-3-08 The forum of the most 15 "green" cities in Israel

EHS- Tech Ltd. congratulates the 15 mayors that joined to the forum, the company gives consultation in the area of renewable energies and reduction of the green house gases to several cities to promote the intiative.

6-3-08 EHS Tech Ltd. did a unique project and the first one in Israel for energy saving in cooling rooms of -20°C

In a unique project and the first one of its kind in Israel, lighting fixture were installed for energy saving by 77% and with keeping the light intensity that was before installation.

All news

 

Energy Saving Characteristics

 

a. The output starts 2~3 seconds after power supply is switched on. after 60 seconds for fluorescent light and 15 minutes for HID the voltage graually drops and starts to save energy.

 

b. Over current protection: When the current is over the rated current,EHS-ILT will stop the output.The larger the over current is, the sooner EHS-ILT stops the output.

 

c. for fluorescent energy saver, depending noncurrent the energy saving is different:

 

Larger energy saving

 

 

Smaller energy saving

 

 

No energy saving

 

 

i.SLT010AS50:

  

Larger energy saving: the current is 1.3A~9.5A, but from smaller energy saving or no energy saving returning to larger energy saving the current has to be larger than 2.6A.

Smaller energy saving: The current is 0.75A~1.3A, but from no energy saving returning to smaller energy saving the current has to be larger than 1.3A and from no energy saving to larger energy saving the current has to be larger than 2.6A.

No energy saving: The current is smaller than 0.75A. 

 

 

i.SLT015AS50:

  

Larger energy saving: the current is 2.0A~14A, but from smaller energy saving or no energy saving returning to larger energy saving the current has to be larger than 4.0A.

Smaller energy saving: The current is 1.5A~2.0A, but from no energy saving returning to smaller energy saving the current has to be larger than 2.0A and from no energy saving to larger energy saving the current has to be larger than 4.0A.

No energy saving: The current is smaller than 1.5A.

 

  

i.SLT025AS50:

  

Larger energy saving: the current is 1.7A~24A, but from smaller energy saving or no energy saving returning to larger energy saving the current has to be larger than 4.8A.

Smaller energy saving: The current is 1.0A~1.7A, but from no energy saving returning to smaller energy saving the current has to be larger than 1.7A and from no energy saving to larger energy saving the current has to be larger than 4.8A.

No energy saving: The current is smaller than 1.0A.

 

 

i.SLT040AS50:

  

Larger energy saving: the current is 2.5A~39A, but from smaller energy saving or no energy saving returning to larger energy saving the current has to be larger than 7.6A.

Smaller energy saving: The current is 1.0A~2.5A, but from no energy saving returning to smaller energy saving the current has to be larger than 2.5A and from no energy saving to larger energy saving the current has to be larger than 7.6A.

No energy saving: The current is smaller than 1.0A.